Eaton BiWire Ultra Common Detector Base (FXN520)

Eaton BiWire Ultra Common Detector Base (FXN520)

Eaton BiWire Ultra Common Detector Base (FXN520)

BiWire Ultra Can Reduce Wiring Requirements By Up To 50%

  • 2 Year Guarantee
  • Quick & Simple Install
  • Stand Off Fixing Feature
  • Selectable Detector Locking
  • Accepts Side Entry Surface Cables
  • £2.69
    SKU
    FXN520

    In stock

    Delivery 1 - 2 days

    Eaton BiWire Ultra Common Detector Base

     

    Midshires Comments:

    The FXN520 conventional standard base has been specifically designed to be compatible with the JSB range of conventional detectors.

     

    Features & Benefits:

    • Quick & Simple To Install
    • Separate Zone In And Zone Out Terminals
    • Stand Off Fixing Feature
    • Selectable Detector Locking
    • Accepts Side Entry Surface Cables
    • Common Base For JSB Conventional Detectors

     

    Product Information:

    This standard base has been designed for flexibility, simplicity and speed of installation. It incorporates purpose designed devices to provide fault warning if detector is removed whilst maintaining full zone wiring integrity.

    The base has a schotty diode in series with the negative terminals to enable fault monitoring and allow the circuit to continue if a detector is removed.

     

    BS EN54-23:

    BS EN54-23 specifies the requirements, test methods and performance criteria for VADs in fire detection and fire alarm systems. Manufacturers must now present the products performance data in a uniform manner so that they can be directly compared and their suitability assessed for particular applications. All VADs sold for fire use in EU countries must be manufactured and certified to these requirements by 1st March 2013. For countries such as the UK which do not currently require CE marking to the CPD, compliance will be enforced from July 1 2013 when the Construction Products Directive (CPD) is replaced by the Construction Products Regulation (CPR). The FIA and LPCB have jointly published COP0001 Code of Practice for Visual Alarm Devices used for Fire Warning, which directly compliments BS EN54-23 and BS 5839-1. It provides guidance and recommendations on the planning, design, installation, commissioning and maintenance of VADs in and around buildings, other than single-family dwellings.

     

    More Information
    Manufacturer Eaton
    Description

    Eaton BiWire Ultra Common Detector Base

     

    Midshires Comments:

    The FXN520 conventional standard base has been specifically designed to be compatible with the JSB range of conventional detectors.

     

    Features & Benefits:

    • Quick & Simple To Install
    • Separate Zone In And Zone Out Terminals
    • Stand Off Fixing Feature
    • Selectable Detector Locking
    • Accepts Side Entry Surface Cables
    • Common Base For JSB Conventional Detectors

     

    Product Information:

    This standard base has been designed for flexibility, simplicity and speed of installation. It incorporates purpose designed devices to provide fault warning if detector is removed whilst maintaining full zone wiring integrity.

    The base has a schotty diode in series with the negative terminals to enable fault monitoring and allow the circuit to continue if a detector is removed.

     

    BS EN54-23:

    BS EN54-23 specifies the requirements, test methods and performance criteria for VADs in fire detection and fire alarm systems. Manufacturers must now present the products performance data in a uniform manner so that they can be directly compared and their suitability assessed for particular applications. All VADs sold for fire use in EU countries must be manufactured and certified to these requirements by 1st March 2013. For countries such as the UK which do not currently require CE marking to the CPD, compliance will be enforced from July 1 2013 when the Construction Products Directive (CPD) is replaced by the Construction Products Regulation (CPR). The FIA and LPCB have jointly published COP0001 Code of Practice for Visual Alarm Devices used for Fire Warning, which directly compliments BS EN54-23 and BS 5839-1. It provides guidance and recommendations on the planning, design, installation, commissioning and maintenance of VADs in and around buildings, other than single-family dwellings.

     